{"product_id":"hpe-msa-2060-16gb-fibre-channel-sff-storage-r0q74b","title":"HPE MSA 2060 16Gb Fibre Channel SFF Storage, with dual 4-port 16Gb Fibre Channel controllers and a 24 × SFF 2.5-inch drive-bay chassis | R0Q74B","description":"\u003ch2\u003eHPE MSA 2060 16Gb Fibre Channel SFF Storage, with dual 4-port 16Gb Fibre Channel controllers and a 24 × SFF 2.5-inch drive-bay chassis | R0Q74B\u003c\/h2\u003e\n\u003cp\u003eThe HPE MSA 2060 16Gb Fibre Channel SFF Storage is a 2U Gen6 SAN storage array designed for Fibre Channel environments, virtualization, databases, and general enterprise storage. The SFF enclosure provides 24 × 2.5-inch drive bays and uses dual redundant MSA 2060 controllers.\u003c\/p\u003e\n\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eFibre Channel Controllers\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e\u003cstrong\u003e2 × HPE MSA 2060 16Gb Fibre Channel Storage Controllers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eEach controller has:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e4 × 16Gb Fibre Channel host ports\u003c\/li\u003e\n\u003cli\u003e12Gb SAS expansion connectivity\u003c\/li\u003e\n\u003cli\u003eActive\/active controller operation\u003c\/li\u003e\n\u003cli\u003eRedundant architecture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003eTotal = 8 × 16Gb Fibre Channel host ports\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003eSFF Drive Bays\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e\u003cstrong\u003e24 × SFF 2.5-inch drive bays\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSSDs\u003c\/li\u003e\n\u003cli\u003e10K Enterprise SAS HDDs\u003c\/li\u003e\n\u003cli\u003eMidline SAS HDDs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSSD\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e960GB\u003c\/li\u003e\n\u003cli\u003e1.92TB\u003c\/li\u003e\n\u003cli\u003e3.84TB\u003c\/li\u003e\n\u003cli\u003e7.68TB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnterprise SAS HDD\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e600GB 10K\u003c\/li\u003e\n\u003cli\u003e1.2TB 10K\u003c\/li\u003e\n\u003cli\u003e1.8TB 10K\u003c\/li\u003e\n\u003cli\u003e2.4TB 10K\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDrives Are NOT Automatically Included\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eR0Q74B is a base storage array configuration.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSFF array chassis\u003c\/li\u003e\n\u003cli\u003e2 × MSA 2060 16Gb FC controllers\u003c\/li\u003e\n\u003cli\u003e2 × AC power supplies\u003c\/li\u003e\n\u003cli\u003e2 × 1.5m PDU cables\u003c\/li\u003e\n\u003cli\u003eRack-mount kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDrives are not included in the base configuration.\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch2\u003eFibre Channel SFP+ Transceivers\u003c\/h2\u003e\n\u003ch3\u003eThe base R0Q74B does not include SFP transceivers.\u003c\/h3\u003e\n\u003cp\u003eC8R24B — HPE MSA 16Gb Short Wave Fibre Channel SFP+ 4-pack Transceiver\u003c\/p\u003e\n\u003cp\u003eHPE specifies that the FC array can be configured with \u003cstrong\u003efour or eight SFPs\u003c\/strong\u003e, with a minimum of one 4-pack required for FC models. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eExpansion\u003c\/h2\u003e\n\u003cp\u003eThe MSA 2060 can be expanded using additional MSA 2060 drive enclosures.\u003c\/p\u003e\n\u003ch3\u003eSFF Expansion - 24 × 2.5-inch drives\u003c\/h3\u003e\n\u003cp\u003eR0Q40B — HPE MSA 2060 SAS 12G 2U 24-disk SFF Drive Enclosure\u003c\/p\u003e\n\u003ch3\u003eLFF Expansion - 12 × 3.5-inch drives\u003c\/h3\u003e\n\u003cp\u003eR0Q39B — HPE MSA 2060 SAS 12G 2U 12-disk LFF Drive Enclosure\u003c\/p\u003e\n\u003cp\u003eThe system supports up to 9 additional drive enclosures, and SFF and LFF enclosures can be mixed. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eMaximum Drive Configuration\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eConfiguration\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMaximum\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFF drives\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e240\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFF drives\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e120\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFF raw capacity\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7.37PB\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFF raw capacity\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2.88PB\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion enclosures\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e9\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eHPE lists a maximum of 240 SFF or 120 LFF drives for the MSA 2060 platform. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eRAID Support\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRAID 0 — read cache only\u003c\/li\u003e\n\u003cli\u003eRAID 1\u003c\/li\u003e\n\u003cli\u003eRAID 5\u003c\/li\u003e\n\u003cli\u003eRAID 6\u003c\/li\u003e\n\u003cli\u003eRAID 10\u003c\/li\u003e\n\u003cli\u003eMSA-DP+\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMSA-DP+\u003c\/h3\u003e\n\u003cp\u003eMSA-DP+ is HPE's distributed-parity technology designed to provide efficient storage utilization and distributed spare capacity.\u003c\/p\u003e\n\u003ch2\u003eStorage Management Features\u003c\/h2\u003e\n\u003ch3\u003eThin Technologies\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThin Provisioning\u003c\/li\u003e\n\u003cli\u003eSpace Reclamation\u003c\/li\u003e\n\u003cli\u003eThin Rebuild\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTiering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePerformance Tier\u003c\/li\u003e\n\u003cli\u003eStandard Tier\u003c\/li\u003e\n\u003cli\u003eArchive Tier\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eData Protection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSnapshots\u003c\/li\u003e\n\u003cli\u003eVolume Copy\u003c\/li\u003e\n\u003cli\u003eRemote Snap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOther Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVirtual Tier Affinity\u003c\/li\u003e\n\u003cli\u003eStorage pooling\u003c\/li\u003e\n\u003cli\u003eSSD Read Cache\u003c\/li\u003e\n\u003cli\u003eSelf-encrypting drive support\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eCache \u0026amp; System Resources\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" style=\"width: 100%; height: 176.344px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth class=\"last:pe-10\" style=\"width: 77.7655%; height: 19.5938px;\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\" style=\"width: 19.4027%; height: 19.5938px;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 77.7655%; height: 19.5938px;\"\u003eSystem Cache + Memory\u003c\/td\u003e\n\u003ctd style=\"width: 19.4027%; height: 19.5938px;\"\u003e24GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 77.7655%; height: 19.5938px;\"\u003eMaximum Read Cache\u003c\/td\u003e\n\u003ctd style=\"width: 19.4027%; height: 19.5938px;\"\u003e8TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 77.7655%; height: 19.5938px;\"\u003eMaximum Pools\u003c\/td\u003e\n\u003ctd style=\"width: 19.4027%; height: 19.5938px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 77.7655%; height: 19.5938px;\"\u003eAddressable Capacity per Pool\u003c\/td\u003e\n\u003ctd style=\"width: 19.4027%; height: 19.5938px;\"\u003e4PiB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 77.7655%; height: 19.5938px;\"\u003eMaximum Volumes\u003c\/td\u003e\n\u003ctd style=\"width: 19.4027%; height: 19.5938px;\"\u003e512\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 77.7655%; height: 19.5938px;\"\u003eMaximum Snapshots\u003c\/td\u003e\n\u003ctd style=\"width: 19.4027%; height: 19.5938px;\"\u003e512\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 77.7655%; height: 19.5938px;\"\u003eMaximum Hosts\u003c\/td\u003e\n\u003ctd style=\"width: 19.4027%; height: 19.5938px;\"\u003e512\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 77.7655%; height: 19.5938px;\"\u003eMaximum Initiators\u003c\/td\u003e\n\u003ctd style=\"width: 19.4027%; height: 19.5938px;\"\u003e1,024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003ePerformance\u003c\/h2\u003e\n\u003cp\u003eHPE specifies the MSA 2060 platform at \u003cstrong\u003eup to 395,000 IOPS\u003c\/strong\u003e under HPE's test conditions.\u003c\/p\u003e\n\u003cp\u003eThis is a platform-level maximum and shouldn't be interpreted as guaranteed performance for every R0Q74B configuration. Actual performance depends on:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNumber of drives\u003c\/li\u003e\n\u003cli\u003eSSD vs HDD\u003c\/li\u003e\n\u003cli\u003eRAID level\u003c\/li\u003e\n\u003cli\u003eWorkload\u003c\/li\u003e\n\u003cli\u003eHost configuration\u003c\/li\u003e\n\u003cli\u003eFC infrastructure\u003c\/li\u003e\n\u003cli\u003eQueue depth\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eController Architecture\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eDual active\/active controllers\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eController redundancy\u003c\/li\u003e\n\u003cli\u003eMultiple host paths\u003c\/li\u003e\n\u003cli\u003eImproved availability\u003c\/li\u003e\n\u003cli\u003eFailover capability\u003c\/li\u003e\n\u003cli\u003eLoad balancing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eExpansion Connectivity\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e\u003cstrong\u003e12Gb SAS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe MSA 2060 controllers provide SAS expansion ports for connecting additional MSA drive enclosures. This is not the same as the host interface.\u003c\/p\u003e\n\u003cp\u003eHost: 16Gb Fibre Channel\u003cbr\u003eExpansion: 12Gb SAS\u003c\/p\u003e\n\u003ch2\u003eSupported Operating Systems\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWindows Server 2022\u003c\/li\u003e\n\u003cli\u003eWindows Server 2019\u003c\/li\u003e\n\u003cli\u003eWindows Server 2016\u003c\/li\u003e\n\u003cli\u003eVMware vSphere 6.7\u003c\/li\u003e\n\u003cli\u003eRed Hat Linux 8\u003c\/li\u003e\n\u003cli\u003eSUSE SLES 15\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePhysical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eField\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2U\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e8.9 cm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e44.5 cm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50.8 cm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5 kg\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrive Form Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5-inch SFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrive Bays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003ePower\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e2 × AC power supplies\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eRedundant power architecture\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e2 × 1.5m PDU power cords\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e94% efficient power supplies on the B-suffix configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat Is Included\u003c\/h2\u003e\n\u003ch3\u003eR0Q74B Base Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHPE MSA 2060 SFF array chassis\u003c\/li\u003e\n\u003cli\u003e2 × MSA 2060 16Gb Fibre Channel controllers\u003c\/li\u003e\n\u003cli\u003e8 × 16Gb FC host ports total\u003c\/li\u003e\n\u003cli\u003e2 × AC power supplies\u003c\/li\u003e\n\u003cli\u003e2 × 1.5m PDU power cables\u003c\/li\u003e\n\u003cli\u003eRack-mount kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNot Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHDDs\/SSDs\u003c\/li\u003e\n\u003cli\u003eFibre Channel SFP+ transceivers\u003c\/li\u003e\n\u003cli\u003eAdditional drive enclosures\u003c\/li\u003e\n\u003cli\u003eAdditional storage media\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eComparison R0Q73B vs R0Q74B\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003e\u003cstrong\u003eR0Q73B\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003e\u003cstrong\u003eR0Q74B\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMSA 2060\u003c\/td\u003e\n\u003ctd\u003eMSA 2060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003e16Gb FC\u003c\/td\u003e\n\u003ctd\u003e16Gb FC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControllers\u003c\/td\u003e\n\u003ctd\u003e2 × 4-port\u003c\/td\u003e\n\u003ctd\u003e2 × 4-port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal FC Ports\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Form Factor\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLFF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSFF\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Drive Bays\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e12 × 3.5\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e24 × 2.5\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e2U\u003c\/td\u003e\n\u003ctd\u003e2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8.9 × 44.5 × 50.8 cm\u003c\/td\u003e\n\u003ctd\u003e8.9 × 44.5 × 50.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Advantage\u003c\/td\u003e\n\u003ctd\u003eHigher-capacity LFF drives\u003c\/td\u003e\n\u003ctd\u003eHigher drive density\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"HPE","offers":[{"title":"Default Title","offer_id":47603340738644,"sku":"AS-R0Q74B","price":23699.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0619\/7909\/9220\/files\/HPE_MSA_2060_16Gb_Fibre_Channel_SFF_Storage_6.png?v=1788071439","url":"https:\/\/www.amasouq.ae\/products\/hpe-msa-2060-16gb-fibre-channel-sff-storage-r0q74b","provider":"YOUR ONLINE TECH  STORE","version":"1.0","type":"link"}