{"title":"HPE MSA 2062 Storage Array","description":null,"products":[{"product_id":"hpe-msa-2062-10gbe-iscsi-sff-storage-r0q82b","title":"HPE MSA 2062 10GbE iSCSI SFF Storage | R0Q82B, with 2 × 1.92TB SSD, dual 4-port 10\/25GbE iSCSI controllers and Advanced Data Services license | 3 Years Warranty","description":"\u003ch2\u003eHPE MSA 2062 10GbE iSCSI SFF Storage | R0Q82B | 3 Years Warranty\u003c\/h2\u003e\n\u003cp\u003eThe HPE MSA 2062 10GbE iSCSI SFF Storage (R0Q82B) is a 2U hybrid-flash SAN storage array designed for SMB, remote-office, virtualization, and application workloads. It includes dual 10\/25GbE iSCSI controllers, two 1.92TB Read Intensive SFF SSDs, 24 SFF drive bays, and an Advanced Data Services license.\u003c\/p\u003e\n\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eStorage Controllers\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e2 × HPE MSA 2060 10\/25GbE iSCSI Storage Controllers\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e4 × 10\/25GbE iSCSI ports\u003c\/li\u003e\n\u003cli\u003eRedundant controller architecture\u003c\/li\u003e\n\u003cli\u003eMultiple host connectivity paths\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e4 ports × 2 controllers = 8 total iSCSI host ports. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e10GbE \/ 25GbE iSCSI Connectivity\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eComponent\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eController 1\u003c\/td\u003e\n\u003ctd\u003e4 × 10\/25GbE iSCSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController 2\u003c\/td\u003e\n\u003ctd\u003e4 × 10\/25GbE iSCSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e8 × 10\/25GbE iSCSI ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eIncluded SSD Storage\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e2 × 1.92TB Read Intensive SFF SSD\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e1.92TB × 2 = 3.84TB\u003c\/p\u003e\n\u003cp\u003eThese are 2.5-inch SFF Read Intensive SSDs. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eDrive Bays\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e\u003cstrong\u003e24 × SFF 2.5-inch drives\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSSD\u003c\/li\u003e\n\u003cli\u003eEnterprise SAS HDD\u003c\/li\u003e\n\u003cli\u003eMidline SAS HDD\u003c\/li\u003e\n\u003cli\u003eSelf-encrypting drives, where supported\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe MSA 2062 can combine SSD and HDD media to create a hybrid-flash storage system. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eExpansion\u003c\/h2\u003e\n\u003ch3\u003eSFF expansion\u003c\/h3\u003e\n\u003cp\u003e24-drive SFF MSA 2060 expansion enclosure\u003c\/p\u003e\n\u003ch3\u003eLFF expansion\u003c\/h3\u003e\n\u003cp\u003e12-drive LFF MSA 2060 expansion enclosure\u003c\/p\u003e\n\u003ch2\u003eMaximum Storage Capacity\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eExpansion\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMaximum Capacity\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFF expansion\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1,831.68TB\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFF expansion\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2,332.80TB\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eAdvanced Data Services License\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSnapshots\u003c\/li\u003e\n\u003cli\u003eVolume Copy\u003c\/li\u003e\n\u003cli\u003eRemote Snap\u003c\/li\u003e\n\u003cli\u003eThin Provisioning\u003c\/li\u003e\n\u003cli\u003eStorage tiering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHybrid Flash Architecture\u003c\/h2\u003e\n\u003cp\u003eSSD + Enterprise SAS HDD + Midline SAS HDD\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePerformance\u003c\/li\u003e\n\u003cli\u003eCapacity\u003c\/li\u003e\n\u003cli\u003eCost\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePerformance\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDrive configuration\u003c\/li\u003e\n\u003cli\u003eRAID\/data protection configuration\u003c\/li\u003e\n\u003cli\u003eWorkload\u003c\/li\u003e\n\u003cli\u003eHost connectivity\u003c\/li\u003e\n\u003cli\u003eCache\u003c\/li\u003e\n\u003cli\u003eNumber of controllers\/paths\u003c\/li\u003e\n\u003cli\u003eApplication workload\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eData Protection\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRAID 0\u003c\/li\u003e\n\u003cli\u003eRAID 1\u003c\/li\u003e\n\u003cli\u003eRAID 5\u003c\/li\u003e\n\u003cli\u003eRAID 6\u003c\/li\u003e\n\u003cli\u003eRAID 10\u003c\/li\u003e\n\u003cli\u003eMSA-DP+\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMSA-DP+\u003c\/h3\u003e\n\u003cp\u003eHPE's \u003cstrong\u003eMSA-DP+\u003c\/strong\u003e technology provides distributed spare capacity across the disk group rather than relying on a traditional dedicated hot spare.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRebuild performance\u003c\/li\u003e\n\u003cli\u003eStorage utilization\u003c\/li\u003e\n\u003cli\u003eAvailability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAutomated Tiering\u003c\/h2\u003e\n\u003cp\u003eMSA 2062 supports automated storage tiering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSSD → Performance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnterprise SAS HDD → Standard\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMidline SAS HDD → Capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003eRemote Replication\u003c\/h2\u003e\n\u003cp\u003eThe MSA 2062 supports \u003cstrong\u003eRemote Snap\u003c\/strong\u003e for replication.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDisaster recovery\u003c\/li\u003e\n\u003cli\u003eData replication\u003c\/li\u003e\n\u003cli\u003eSecondary storage systems\u003c\/li\u003e\n\u003cli\u003eBusiness continuity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHPE specifically identifies remote replication over Fibre Channel or iSCSI as a supported MSA 2062 capability. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eVirtualization\u003c\/h2\u003e\n\u003cp\u003eThe MSA 2062 is designed for virtualized environments and supports VMware environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVMware vSphere 6.7\u003c\/li\u003e\n\u003cli\u003eWindows Server 2016\u003c\/li\u003e\n\u003cli\u003eWindows Server 2019\u003c\/li\u003e\n\u003cli\u003eWindows Server 2022\u003c\/li\u003e\n\u003cli\u003eRed Hat Linux 8\u003c\/li\u003e\n\u003cli\u003eSUSE SLES 15 \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eForm Factor \u0026amp; Physical Dimensions\u003c\/h2\u003e\n\u003ch3\u003eRack Size\u003c\/h3\u003e\n\u003cp\u003e2U\u003c\/p\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cp\u003e8.9 × 44.5 × 50.8 cm\u003c\/p\u003e\n\u003ch3\u003eWeight\u003c\/h3\u003e\n\u003cp\u003e5.0 kg\u003c\/p\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eField\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e44.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.9 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003ePower\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e2 × AC power supplies\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eRedundant power architecture\u003c\/li\u003e\n\u003cli\u003e1.5m PDU power cords\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSFP Transceivers\u003c\/h2\u003e\n\u003ch3\u003eSFP transceivers are NOT included with R0Q82B.\u003c\/h3\u003e\n\u003cp\u003eHPE states that SFPs are not included with the base MSA 2062 storage systems. Appropriate Gen6 SFP options must be purchased separately for the Fibre Channel and 10GbE iSCSI models. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor 10Gb iSCSI, HPE offers the appropriate short-range SFP+ transceiver options.\u003c\/p\u003e\n\u003ch2\u003eComplete Technical Specification\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eHPE MSA 2062 R0Q82B\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMSA Storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMSA 2062\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGeneration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGen6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eR0Q82B\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHybrid-Flash SAN Storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2U\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrive Form Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSFF 2.5-inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrive Bays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e24 SFF\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded SSDs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2 × 1.92TB RI SFF SSD\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded Raw SSD Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3.84TB\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControllers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2 × MSA 2060 10\/25GbE iSCSI\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePorts per Controller\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Host Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e8\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHost Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10\/25GbE iSCSI\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSFPs Included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNo\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdvanced Data Services\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpansion Enclosures\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSFF Expansion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24-drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLFF Expansion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum SFF Expansion Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1,831.68TB\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum LFF Expansion Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2,332.80TB\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Performance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 395,000 IOPS*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRAID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRAID 0\/1\/5\/6\/10, MSA-DP+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Tiering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Snap\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThin Provisioning\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSnapshot\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVolume Copy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMSA Storage Management Utility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWindows Server, VMware, Red Hat, SUSE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e8.9 × 44.5 × 50.8 cm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5.0 kg\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supplies\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 × AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3-Year Limited\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty Service\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eParts exchange, next-business-day delivery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e* HPE's stated performance figure is based on its internal testing methodology. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eWhat is Included?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHPE MSA 2062 SFF storage array\u003c\/li\u003e\n\u003cli\u003eMSA 2060-branded SFF chassis\u003c\/li\u003e\n\u003cli\u003e2 × 10\/25GbE iSCSI controllers\u003c\/li\u003e\n\u003cli\u003e2 × 1.92TB Read Intensive SFF SSDs\u003c\/li\u003e\n\u003cli\u003e3.84TB total raw SSD capacity\u003c\/li\u003e\n\u003cli\u003eAdvanced Data Services license\u003c\/li\u003e\n\u003cli\u003e2 × AC power supplies\u003c\/li\u003e\n\u003cli\u003e2 × 1.5m PDU power cords\u003c\/li\u003e\n\u003cli\u003eRack-mount kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNot Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e❌ 10GbE iSCSI SFP+ transceivers\u003c\/li\u003e\n\u003cli\u003e❌ Additional storage drives\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eDifference \u003cstrong\u003eMSA 2060 \u0026amp; MSA 2062\u003c\/strong\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eMSA 2060\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCan be a diskless\/base array\u003c\/li\u003e\n\u003cli\u003eDrives are purchased separately\u003c\/li\u003e\n\u003cli\u003eController type depends on the specific SKU\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMSA 2062\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUses the same MSA Gen6 platform\/chassis\u003c\/li\u003e\n\u003cli\u003eComes with 2 × 1.92TB SSDs\u003c\/li\u003e\n\u003cli\u003eIncludes Advanced Data Services\u003c\/li\u003e\n\u003cli\u003eSold as a more complete hybrid-flash configuration\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HPE","offers":[{"title":"Default Title","offer_id":47594781016148,"sku":"AS-R0Q82B","price":39451.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0619\/7909\/9220\/files\/HPE_MSA_2062_10GbE_iSCSI_SFF1.png?v=1787954571"},{"product_id":"hpe-msa-2062-16gb-fibre-channel-sff-storage-r0q80b","title":"HPE MSA 2062 16Gb Fibre Channel SFF Storage | R0Q80B, with 2 × 1.92TB SSD, dual 4-port 16Gb FC controllers and Advanced Data Services license | 3 Years Warranty","description":"\u003ch2\u003eHPE MSA 2062 16Gb Fibre Channel SFF Storage | R0Q80B | 3 Years Warranty\u003c\/h2\u003e\n\u003cp\u003eThe HPE MSA 2062 16Gb Fibre Channel SFF Storage (R0Q80B) is a flash-enabled Gen6 SAN storage array featuring an HPE MSA 2060 SFF chassis, two 4-port 16Gb Fibre Channel controllers, two 1.92TB Read Intensive SFF SSDs, and a pre-installed Advanced Data Services license. It supports up to 24 SFF drives in the base enclosure and can be expanded with additional MSA 2060 SFF or LFF drive enclosures.\u003c\/p\u003e\n\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eController Configuration\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e2 × HPE MSA 2060 16Gb Fibre Channel Storage Controllers\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4 × 16Gb Fibre Channel ports\u003c\/li\u003e\n\u003cli\u003eRedundant controller architecture\u003c\/li\u003e\n\u003cli\u003eIndependent host connectivity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e8 × 16Gb Fibre Channel host ports\u003c\/p\u003e\n\u003ch2\u003eIncluded SSD Storage\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e2 × 1.92TB Read Intensive SFF SSD\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eTotal raw flash capacity: 3.84TB\u003c\/p\u003e\n\u003cp\u003eThese two SSDs are factory integrated into the array. HPE describes the MSA 2062 as starting with \u003cstrong\u003e3.84TB of embedded flash capacity\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eDrive Capacity\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e24 × 2.5-inch SFF drives\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRead Intensive SSD\u003c\/li\u003e\n\u003cli\u003eEnterprise SAS HDD\u003c\/li\u003e\n\u003cli\u003eMidline SAS HDD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHPE currently lists SFF SSD capacities of \u003cstrong\u003e960GB, 1.92TB, 3.84TB and 7.68TB\u003c\/strong\u003e, while SFF 10K HDD options include \u003cstrong\u003e600GB, 1.2TB, 1.8TB and 2.4TB\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eExpansion\u003c\/h2\u003e\n\u003cp\u003eThe MSA 2062 can be expanded with up to \u003cstrong\u003e9 additional MSA 2060 drive enclosures\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eSupported expansion includes:\u003c\/p\u003e\n\u003ch3\u003eSFF\u003c\/h3\u003e\n\u003cp\u003e24-drive SFF enclosure\u003c\/p\u003e\n\u003ch3\u003eLFF\u003c\/h3\u003e\n\u003cp\u003e12-drive LFF enclosure\u003c\/p\u003e\n\u003cp\u003eHPE also supports mixing SFF and LFF array\/enclosures. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eMaximum configuration\u003c\/h3\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eConfiguration\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMaximum\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFF drives\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e240\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFF + LFF\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e24 SFF + 108 LFF\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAll-SFF raw capacity\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1,831.68TB\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFF + LFF raw capacity\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2,764.8TB\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eFibre Channel Connectivity\u003c\/h2\u003e\n\u003cp\u003eThe R0Q80B is the 16Gb Fibre Channel version of the MSA 2062.\u003c\/p\u003e\n\u003ch3\u003eConnectivity\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e8 × 16Gb FC host ports\u003c\/li\u003e\n\u003cli\u003e4 ports per controller\u003c\/li\u003e\n\u003cli\u003e2 redundant controllers\u003c\/li\u003e\n\u003cli\u003e8\/16Gb Fibre Channel connectivity\u003c\/li\u003e\n\u003cli\u003eAuto-negotiation down to 8Gb FC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSFP+ requirement\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFC SFP+ transceivers are not included.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHPE specifies that MSA 2062 FC systems require the appropriate Gen6 SFP option. The recommended 4-pack for this model is:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eC8R24B — HPE MSA 16Gb Short Wave Fibre Channel SFP+ 4-pack Transceiver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA minimum of one 4-pack is required for Fibre Channel models. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis is particularly relevant to your inventory because you have \u003cstrong\u003eC8R24B\u003c\/strong\u003e in stock.\u003c\/p\u003e\n\u003ch2\u003eStorage Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThin Provisioning\u003c\/li\u003e\n\u003cli\u003eSpace Reclamation\u003c\/li\u003e\n\u003cli\u003eThin Rebuild\u003c\/li\u003e\n\u003cli\u003eAutomated Tiering\u003c\/li\u003e\n\u003cli\u003eSSD Read Cache Extension\u003c\/li\u003e\n\u003cli\u003eVolume Copy\u003c\/li\u003e\n\u003cli\u003eSnapshots\u003c\/li\u003e\n\u003cli\u003eRemote Snap\u003c\/li\u003e\n\u003cli\u003eVirtual Tier Affinity\u003c\/li\u003e\n\u003cli\u003eMSA-DP+\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRAID Support\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRAID 0\u003c\/strong\u003e — Read Cache Only\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRAID 1\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRAID 5\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRAID 6\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRAID 10\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMSA-DP+\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMSA-DP+\u003c\/h3\u003e\n\u003cp\u003eMSA-DP+ provides:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated sparing\u003c\/li\u003e\n\u003cli\u003eFast rebuilds\u003c\/li\u003e\n\u003cli\u003eImproved sequential performance\u003c\/li\u003e\n\u003cli\u003eIncremental disk-group expansion\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAdvanced Data Services\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eAdvanced Data Services LTU is included and pre-installed\u003c\/strong\u003e with MSA 2062.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAdvanced snapshots\u003c\/li\u003e\n\u003cli\u003eRemote Snap\u003c\/li\u003e\n\u003cli\u003eVolume Copy\u003c\/li\u003e\n\u003cli\u003eThin Provisioning\u003c\/li\u003e\n\u003cli\u003eStorage management features\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHPE specifies \u003cstrong\u003e64 snapshots per array as standard\u003c\/strong\u003e, increasing to \u003cstrong\u003e512 snapshots with the Advanced Data Services license\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCache \u0026amp; System Resources\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" style=\"width: 100%; height: 176.344px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth class=\"last:pe-10\" style=\"width: 83.0005%; height: 19.5938px;\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\" style=\"width: 14.1676%; height: 19.5938px;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 83.0005%; height: 19.5938px;\"\u003e\u003cstrong\u003eData Read\/Write Cache + System Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 14.1676%; height: 19.5938px;\"\u003e\u003cstrong\u003e24GB\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 83.0005%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum Read Cache\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 14.1676%; height: 19.5938px;\"\u003e\u003cstrong\u003e8TB\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 83.0005%; height: 19.5938px;\"\u003e\u003cstrong\u003eStorage Pools\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 14.1676%; height: 19.5938px;\"\u003eUp to 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 83.0005%; height: 19.5938px;\"\u003e\u003cstrong\u003eAddressable Capacity per Pool\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 14.1676%; height: 19.5938px;\"\u003e4 PiB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 83.0005%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum Volumes per Pool\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 14.1676%; height: 19.5938px;\"\u003e512\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 83.0005%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum Volumes per Array\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 14.1676%; height: 19.5938px;\"\u003e1,024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 83.0005%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum Hosts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 14.1676%; height: 19.5938px;\"\u003e512\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 83.0005%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum Initiators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 14.1676%; height: 19.5938px;\"\u003e1,024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003ePower\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e2 × AC power supplies\u003c\/li\u003e\n\u003cli\u003eRedundant power configuration\u003c\/li\u003e\n\u003cli\u003e2 × 1.5m PDU power cords\u003c\/li\u003e\n\u003cli\u003e94% efficient power supplies on the B-suffix SKU\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePhysical Dimensions\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eField\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50.8 cm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e44.5 cm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e8.9 cm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5.0 kg\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2U\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eHPE's datasheet gives the dimensions as \u003cstrong\u003e8.9 × 44.5 × 50.8 cm\u003c\/strong\u003e and weight as \u003cstrong\u003e5.0kg\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eOperating System \/ Platform Support\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWindows Server 2022\u003c\/li\u003e\n\u003cli\u003eWindows Server 2019\u003c\/li\u003e\n\u003cli\u003eWindows Server 2016\u003c\/li\u003e\n\u003cli\u003eVMware vSphere 6.7\u003c\/li\u003e\n\u003cli\u003eRed Hat Linux 8\u003c\/li\u003e\n\u003cli\u003eSUSE SLES 15\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat Is Included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHPE MSA 2060 SFF array chassis\u003c\/li\u003e\n\u003cli\u003e2 × MSA 2060 16Gb FC controllers\u003c\/li\u003e\n\u003cli\u003e2 × 1.92TB Read Intensive SFF SSD\u003c\/li\u003e\n\u003cli\u003eAdvanced Data Services LTU\u003c\/li\u003e\n\u003cli\u003e2 × AC power supplies\u003c\/li\u003e\n\u003cli\u003e2 × 1.5m PDU cords\u003c\/li\u003e\n\u003cli\u003eRack-mount kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFC SFP+ transceivers\u003c\/li\u003e\n\u003cli\u003eAdditional HDDs\/SSDs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HPE","offers":[{"title":"Default Title","offer_id":47602914558036,"sku":"AS-R0Q80B","price":41329.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0619\/7909\/9220\/files\/HPE_MSA_2062_16Gb_Fibre_Channel_SFF_Storage_1.png?v=1788034432"}],"url":"https:\/\/www.amasouq.ae\/collections\/hpe-msa-2062-storage-array.oembed","provider":"YOUR ONLINE TECH  STORE","version":"1.0","type":"link"}