{"title":"HPE MSA 2060 16Gb Fibre Channel SFF Storage","description":"\u003cp\u003eExplore HPE MSA 2060 16Gb Fibre Channel SFF Storage solutions at AMASOUQ.AE, your complete tech store in the UAE. Discover enterprise storage solutions designed for data centres, virtualisation, business-critical applications and demanding IT environments. The HPE MSA 2060 platform combines 16Gb Fibre Channel connectivity with Small Form Factor (SFF) drive support, offering flexible and scalable shared storage for business workloads. Ideal for organisations seeking reliable enterprise storage performance and capacity expansion. Shop HPE MSA 2060 storage solutions in the UAE at the best prices. Contact our sales team to confirm availability, configuration and compatibility.\u003c\/p\u003e","products":[{"product_id":"hpe-msa-2060-16gb-fibre-channel-sff-storage-r0q74b","title":"HPE MSA 2060 16Gb Fibre Channel SFF Storage, with dual 4-port 16Gb Fibre Channel controllers and a 24 × SFF 2.5-inch drive-bay chassis | R0Q74B","description":"\u003ch2\u003eHPE MSA 2060 16Gb Fibre Channel SFF Storage, with dual 4-port 16Gb Fibre Channel controllers and a 24 × SFF 2.5-inch drive-bay chassis | R0Q74B\u003c\/h2\u003e\n\u003cp\u003eThe HPE MSA 2060 16Gb Fibre Channel SFF Storage is a 2U Gen6 SAN storage array designed for Fibre Channel environments, virtualization, databases, and general enterprise storage. The SFF enclosure provides 24 × 2.5-inch drive bays and uses dual redundant MSA 2060 controllers.\u003c\/p\u003e\n\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eFibre Channel Controllers\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e\u003cstrong\u003e2 × HPE MSA 2060 16Gb Fibre Channel Storage Controllers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eEach controller has:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e4 × 16Gb Fibre Channel host ports\u003c\/li\u003e\n\u003cli\u003e12Gb SAS expansion connectivity\u003c\/li\u003e\n\u003cli\u003eActive\/active controller operation\u003c\/li\u003e\n\u003cli\u003eRedundant architecture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003eTotal = 8 × 16Gb Fibre Channel host ports\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003eSFF Drive Bays\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e\u003cstrong\u003e24 × SFF 2.5-inch drive bays\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSSDs\u003c\/li\u003e\n\u003cli\u003e10K Enterprise SAS HDDs\u003c\/li\u003e\n\u003cli\u003eMidline SAS HDDs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSSD\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e960GB\u003c\/li\u003e\n\u003cli\u003e1.92TB\u003c\/li\u003e\n\u003cli\u003e3.84TB\u003c\/li\u003e\n\u003cli\u003e7.68TB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnterprise SAS HDD\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e600GB 10K\u003c\/li\u003e\n\u003cli\u003e1.2TB 10K\u003c\/li\u003e\n\u003cli\u003e1.8TB 10K\u003c\/li\u003e\n\u003cli\u003e2.4TB 10K\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDrives Are NOT Automatically Included\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eR0Q74B is a base storage array configuration.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSFF array chassis\u003c\/li\u003e\n\u003cli\u003e2 × MSA 2060 16Gb FC controllers\u003c\/li\u003e\n\u003cli\u003e2 × AC power supplies\u003c\/li\u003e\n\u003cli\u003e2 × 1.5m PDU cables\u003c\/li\u003e\n\u003cli\u003eRack-mount kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDrives are not included in the base configuration.\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch2\u003eFibre Channel SFP+ Transceivers\u003c\/h2\u003e\n\u003ch3\u003eThe base R0Q74B does not include SFP transceivers.\u003c\/h3\u003e\n\u003cp\u003eC8R24B — HPE MSA 16Gb Short Wave Fibre Channel SFP+ 4-pack Transceiver\u003c\/p\u003e\n\u003cp\u003eHPE specifies that the FC array can be configured with \u003cstrong\u003efour or eight SFPs\u003c\/strong\u003e, with a minimum of one 4-pack required for FC models. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eExpansion\u003c\/h2\u003e\n\u003cp\u003eThe MSA 2060 can be expanded using additional MSA 2060 drive enclosures.\u003c\/p\u003e\n\u003ch3\u003eSFF Expansion - 24 × 2.5-inch drives\u003c\/h3\u003e\n\u003cp\u003eR0Q40B — HPE MSA 2060 SAS 12G 2U 24-disk SFF Drive Enclosure\u003c\/p\u003e\n\u003ch3\u003eLFF Expansion - 12 × 3.5-inch drives\u003c\/h3\u003e\n\u003cp\u003eR0Q39B — HPE MSA 2060 SAS 12G 2U 12-disk LFF Drive Enclosure\u003c\/p\u003e\n\u003cp\u003eThe system supports up to 9 additional drive enclosures, and SFF and LFF enclosures can be mixed. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eMaximum Drive Configuration\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eConfiguration\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMaximum\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFF drives\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e240\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFF drives\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e120\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFF raw capacity\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7.37PB\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFF raw capacity\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2.88PB\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion enclosures\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e9\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eHPE lists a maximum of 240 SFF or 120 LFF drives for the MSA 2060 platform. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eRAID Support\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRAID 0 — read cache only\u003c\/li\u003e\n\u003cli\u003eRAID 1\u003c\/li\u003e\n\u003cli\u003eRAID 5\u003c\/li\u003e\n\u003cli\u003eRAID 6\u003c\/li\u003e\n\u003cli\u003eRAID 10\u003c\/li\u003e\n\u003cli\u003eMSA-DP+\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMSA-DP+\u003c\/h3\u003e\n\u003cp\u003eMSA-DP+ is HPE's distributed-parity technology designed to provide efficient storage utilization and distributed spare capacity.\u003c\/p\u003e\n\u003ch2\u003eStorage Management Features\u003c\/h2\u003e\n\u003ch3\u003eThin Technologies\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThin Provisioning\u003c\/li\u003e\n\u003cli\u003eSpace Reclamation\u003c\/li\u003e\n\u003cli\u003eThin Rebuild\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTiering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePerformance Tier\u003c\/li\u003e\n\u003cli\u003eStandard Tier\u003c\/li\u003e\n\u003cli\u003eArchive Tier\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eData Protection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSnapshots\u003c\/li\u003e\n\u003cli\u003eVolume Copy\u003c\/li\u003e\n\u003cli\u003eRemote Snap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOther Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVirtual Tier Affinity\u003c\/li\u003e\n\u003cli\u003eStorage pooling\u003c\/li\u003e\n\u003cli\u003eSSD Read Cache\u003c\/li\u003e\n\u003cli\u003eSelf-encrypting drive support\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eCache \u0026amp; System Resources\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" style=\"width: 100%; height: 176.344px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth class=\"last:pe-10\" style=\"width: 77.7655%; height: 19.5938px;\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\" style=\"width: 19.4027%; height: 19.5938px;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 77.7655%; height: 19.5938px;\"\u003eSystem Cache + Memory\u003c\/td\u003e\n\u003ctd style=\"width: 19.4027%; height: 19.5938px;\"\u003e24GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 77.7655%; height: 19.5938px;\"\u003eMaximum Read Cache\u003c\/td\u003e\n\u003ctd style=\"width: 19.4027%; height: 19.5938px;\"\u003e8TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 77.7655%; height: 19.5938px;\"\u003eMaximum Pools\u003c\/td\u003e\n\u003ctd style=\"width: 19.4027%; height: 19.5938px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 77.7655%; height: 19.5938px;\"\u003eAddressable Capacity per Pool\u003c\/td\u003e\n\u003ctd style=\"width: 19.4027%; height: 19.5938px;\"\u003e4PiB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 77.7655%; height: 19.5938px;\"\u003eMaximum Volumes\u003c\/td\u003e\n\u003ctd style=\"width: 19.4027%; height: 19.5938px;\"\u003e512\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 77.7655%; height: 19.5938px;\"\u003eMaximum Snapshots\u003c\/td\u003e\n\u003ctd style=\"width: 19.4027%; height: 19.5938px;\"\u003e512\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 77.7655%; height: 19.5938px;\"\u003eMaximum Hosts\u003c\/td\u003e\n\u003ctd style=\"width: 19.4027%; height: 19.5938px;\"\u003e512\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 77.7655%; height: 19.5938px;\"\u003eMaximum Initiators\u003c\/td\u003e\n\u003ctd style=\"width: 19.4027%; height: 19.5938px;\"\u003e1,024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003ePerformance\u003c\/h2\u003e\n\u003cp\u003eHPE specifies the MSA 2060 platform at \u003cstrong\u003eup to 395,000 IOPS\u003c\/strong\u003e under HPE's test conditions.\u003c\/p\u003e\n\u003cp\u003eThis is a platform-level maximum and shouldn't be interpreted as guaranteed performance for every R0Q74B configuration. Actual performance depends on:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNumber of drives\u003c\/li\u003e\n\u003cli\u003eSSD vs HDD\u003c\/li\u003e\n\u003cli\u003eRAID level\u003c\/li\u003e\n\u003cli\u003eWorkload\u003c\/li\u003e\n\u003cli\u003eHost configuration\u003c\/li\u003e\n\u003cli\u003eFC infrastructure\u003c\/li\u003e\n\u003cli\u003eQueue depth\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eController Architecture\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eDual active\/active controllers\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eController redundancy\u003c\/li\u003e\n\u003cli\u003eMultiple host paths\u003c\/li\u003e\n\u003cli\u003eImproved availability\u003c\/li\u003e\n\u003cli\u003eFailover capability\u003c\/li\u003e\n\u003cli\u003eLoad balancing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eExpansion Connectivity\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e\u003cstrong\u003e12Gb SAS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe MSA 2060 controllers provide SAS expansion ports for connecting additional MSA drive enclosures. This is not the same as the host interface.\u003c\/p\u003e\n\u003cp\u003eHost: 16Gb Fibre Channel\u003cbr\u003eExpansion: 12Gb SAS\u003c\/p\u003e\n\u003ch2\u003eSupported Operating Systems\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWindows Server 2022\u003c\/li\u003e\n\u003cli\u003eWindows Server 2019\u003c\/li\u003e\n\u003cli\u003eWindows Server 2016\u003c\/li\u003e\n\u003cli\u003eVMware vSphere 6.7\u003c\/li\u003e\n\u003cli\u003eRed Hat Linux 8\u003c\/li\u003e\n\u003cli\u003eSUSE SLES 15\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePhysical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eField\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2U\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e8.9 cm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e44.5 cm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50.8 cm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5 kg\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrive Form Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5-inch SFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrive Bays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003ePower\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e2 × AC power supplies\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eRedundant power architecture\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e2 × 1.5m PDU power cords\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e94% efficient power supplies on the B-suffix configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat Is Included\u003c\/h2\u003e\n\u003ch3\u003eR0Q74B Base Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHPE MSA 2060 SFF array chassis\u003c\/li\u003e\n\u003cli\u003e2 × MSA 2060 16Gb Fibre Channel controllers\u003c\/li\u003e\n\u003cli\u003e8 × 16Gb FC host ports total\u003c\/li\u003e\n\u003cli\u003e2 × AC power supplies\u003c\/li\u003e\n\u003cli\u003e2 × 1.5m PDU power cables\u003c\/li\u003e\n\u003cli\u003eRack-mount kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNot Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHDDs\/SSDs\u003c\/li\u003e\n\u003cli\u003eFibre Channel SFP+ transceivers\u003c\/li\u003e\n\u003cli\u003eAdditional drive enclosures\u003c\/li\u003e\n\u003cli\u003eAdditional storage media\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eComparison R0Q73B vs R0Q74B\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003e\u003cstrong\u003eR0Q73B\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003e\u003cstrong\u003eR0Q74B\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMSA 2060\u003c\/td\u003e\n\u003ctd\u003eMSA 2060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003e16Gb FC\u003c\/td\u003e\n\u003ctd\u003e16Gb FC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControllers\u003c\/td\u003e\n\u003ctd\u003e2 × 4-port\u003c\/td\u003e\n\u003ctd\u003e2 × 4-port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal FC Ports\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Form Factor\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLFF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSFF\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Drive Bays\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e12 × 3.5\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e24 × 2.5\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e2U\u003c\/td\u003e\n\u003ctd\u003e2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8.9 × 44.5 × 50.8 cm\u003c\/td\u003e\n\u003ctd\u003e8.9 × 44.5 × 50.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Advantage\u003c\/td\u003e\n\u003ctd\u003eHigher-capacity LFF drives\u003c\/td\u003e\n\u003ctd\u003eHigher drive density\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"HPE","offers":[{"title":"Default Title","offer_id":47603340738644,"sku":"AS-R0Q74B","price":22828.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0619\/7909\/9220\/files\/HPE_MSA_2060_16Gb_Fibre_Channel_SFF_Storage_6.png?v=1788071439"}],"url":"https:\/\/www.amasouq.ae\/collections\/hpe-msa-2060-16gb-fibre-channel-sff-storage.oembed","provider":"YOUR ONLINE TECH  STORE","version":"1.0","type":"link"}